• Liquid Cooling Container Antspace HK3 210 Units Of Antminer S19 Pro+ Hydro
  • Liquid Cooling Container Antspace HK3 210 Units Of Antminer S19 Pro+ Hydro
Liquid Cooling Container Antspace HK3 210 Units Of Antminer S19 Pro+ Hydro

Liquid Cooling Container Antspace HK3 210 Units Of Antminer S19 Pro+ Hydro

Product Details:

Brand Name: ANTSPACE
Model Number: ANTSPACE HK3

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Dimensions (L*W*H) (mm) 6058*2438*2896
Delivery Time: Shipping Date: July 1-31, 2022
Payment Terms: L/C, T/T, Western Union
Supply Ability: 100
Get Best Price Contact Now

Detail Information

High Light:

Liquid Cooling Container Antspace HK3

,

Bitmain Antspace HK3

,

AntSpace HK3 system

Product Description

Bitmain Antspace HK3 Liquid Cooling Container Available for sale power distribution cabinets

Bitmain Antspace HK3 Liquid Cooling Container

Built with efficiency and hotter climates in mind, the BITMAIN ANTSPACE HK3 (known as model designation Antbox H3 V2 internally) has a maximum capacity of 210 units of Antminer S19 Pro+ Hydro with total consumption of a little over 1MW. The minimum ASIC quantity to compliment the order will be 195 S19 Pro+ Hydro units per container. This represents an approximate cost of $3,400,000 USD, plus shipping. The AntSpace HK3 is sold as a two-piece stackable set– a cooling tower and mining container. Refer to the brochure in the downloads tab for technical details.

Price for AntSpace does not include door-to-door ocean freight service. Freight costs will be quoted at time of loading as shipping costs vary weekly, and by location. ExWorks / FOB incoterms available. Escrow available. 1 year manufacturer warranty included. S19 Pro+ Hydro warranty void if used outside the AntSpace HK3 system.

Two versions rated for NORTH AMERICA and MIDDLE EAST (GCC) power requirements are available at this time only. AntSpace HK3 may function in countries outside of these regions. March batch with delivery in April and May batch with deliveries until August are available. Please consult a live chat agent for more information.

Specification Details For ANTSPACE HK3

Product Overview  
Version ANTSPACE HK3
Dimensions (L*W*H) (mm) 6058*2438*2896
Miner Capacity 210 units -S19 Hyd. Series miner
Container Certification China Classification Society Certification
Safety Certification North America/Standards:NFPA 79:2021,UL 508A:2018 R8.21,
CSA C22.2 No. 14-18,ANSI/ISO 12100:2012
EU/Standards:EN ISO 12100,EN 60204-1
Operating Power(kW) 1047~1050
PUE(Power Usage Effectiveness) 1.022(Excluding cooling tower)/1.036(Including cooling tower)
Input Voltage and Frequency 415V±5% 60Hz(North America)
400V±5% 50Hz(EU,Middle East)

 

Detailed Characteristics  
Shipping Weight(T) 8
Operating Weight (T) 12
Main Switch of Power Distribution Cabinets(A) 1200(North America)
1250(EU,Middle East)
Rated Current(A) 952
Standard Power(kW) 1049
Maximum Power(kW) 1050
Rated Current per Miner(A) 10
Inlet Cable The inlet cables can withstand high-voltage of above 600V, with the following requirements per phase:
L1 single core cable 600kcMil(300mm²)x4
L2 single core cable 600kcMil(300mm²)x4
L3 single core cable 600kcMil(300mm²)x4
N Single-core cable 600kcMil(300mm²)x4
PE single-core cable 500kcMil(240mm²)x2
Connection Interface(Cooling Tower) DN125(GB/T 9119-2010 PN16 DN125)
Connection Interface(Plate Heat Exchage Interface) DN100(GB/T 9119-2010 PN16 DN100)
Flow Rate(m³/h) >85
Quantity of ANTSPACE powered by one 2500kVA Transformer 2

Specification Details For Dry-Wet Towers

One of the following two Dry-Wet Towers can be chosen based on the personalized demand.

Product Overview  
Type Dry-Wet Tower Traditional Type (DWT-T) Dry-Wet Tower Container Type (DWT-C)
Dimensions(L*W*H)(mm) 5800*2240*4200 6058*2438*2896
Heat Dissipation Capacity(kW) 1000 1000
Outlet Temperature @ 28℃ Wet Bulb Temperature 35℃ 35℃
Container Certification None China Classification Society Certification
Safety Certification North America/Standards: NFPA 79:2021, UL 508A:2018 R8.21,
CSA C22.2 No. 14-18, ANSI/ISO 12100:2012
EU Standards: EN ISO 12100, EN 60204-1
North America/Standards: NFPA 79:2021, UL 508A:2018 R8.21,
CSA C22.2 No. 14-18, ANSI/ISO 12100:2012
EU Standards: EN ISO 12100, EN 60204-1
Operating Power(kW) 14~28 14~28
Motor Rated Voltage and Frequency 415V±5% 60Hz(North America)
400V±5% 50Hz(EU,Middle East)
415V±5% 60Hz(North America)
400V±5% 50Hz(EU,Middle East)
Detailed Characteristics  
Shipping Weight(T) 5 6
Operating Weight(T) 9 10
Connection Interface(Container) DN125(GB/T 9119-2010 PN16 DN125) DN125(GB/T 9119-2010 PN16 DN125)
Water Resupply Pipe Interface DN40(Internal thread) DN40(Internal thread)
Drain Pipe Interface DN65(Internal thread) DN65(Internal thread)
Noise Level @25℃, 16m 70dBA 70dBA
Water Consumption(m³/h) 1~1.5 1~1.5

| Environmental Requirementss


 

Environmental Requirements
1 Cooling tower is required to be placed on flat ground, horizontal degree (±1 degree).
2 The ground surfaced is required to be hardened and stable, able to withstand at least 14-ton load.
3 A 10-ton crane is needed for unloading ANTSPACE and cooling tower.
4 Add-on items such as stairs, transformers, cables, bridge racks and cable distribution boxes are not included in the delivery of ANTSPACE. BITMAIN team can provide design suggestions if needed.
5 Client needs to confirm the opening directon of container and it needs to face air-intake. Door on left is current design by defult.
6 Keep at least 2 meters of air in-take space around the cooling tower.
7 Altitude: ≤3000m. If the altitude is higher than 1000-meter, transformer and switch should be derated, the total power of ANTSPACE must be decreased by 1% for each elevation increment of 100 meters.
8 Operating temperature: -25°C to 40°C. Operating humidity: 10%RH to 90%RH. When the initial coolant temperature is below 20 °C, the internal circulation should be turned on to heat up the coolant to above 20 °C before starting the mining machine.
9 When the ambient temperature is below 5 ℃, the cooling tower can be switched to cold-dry mode.
10 Choose pure water or suitable antifreeze as coolant based on local climate conditions.
11 The suitable ambient temperature for ANTSPACE does not represent the suitable ambient temperature for mining machine.

 